Autosorb-1 Series Specifications

Questions-Feedback

Pressure Transducers
(per manufacturer's specifications)
Autosorb
-1AG
Autosorb
-1-MP
Autosorb
-1C
0 to 1,000 torr yes yes yes
Accuracy: 0.1% full scale
Linearity: 0.05% full scale
Minimum resolvable pressure: 0.00025 torr
Minimum resolvable relative pressure (P/Po): 3.2 x 10-7(nitrogen)
0 to 10 torr no yes yes
Accuracy: 0.15% reading
Temperature coeff. (span): 0.01% reading / oC
Minimum resolvable pressure: 2.5 x 10-6 torr
Minimum resolvable relative pressure (P/Po): 3.2 x 10-9(nitrogen)
0 to 1 torr no yes yes
Accuracy: 0.15% reading
Temperature coeff. (span): 0.01% reading/oC
Minimum resolvable pressure: 2.5 x 10-7 torr
Minimum resolvable relative pressure (P/Po): 3.2 x 10-10(nitrogen)
Ultimate Vacuum(per manufacturer's specifications)
Roughing Pump
<10mtorr <2mbar <2mbar
Dry Roughing Pump
no yes yes
Oil-Free Turbo Molec. Pump:
<3.75 x 10-10 torr
manufacturer's specification)
no yes yes
Adsorbates
Non-corrosive gas (N2, Ar, CO2, C4H10 , etc.)
yes yes yes
Krypton gas ( for very low surface areas )
no yes yes
Ammonia ( Physisorption )
no yes yes
Ammonia ( Chemisorption )
no no yes
Vapors (water and organic solvents)
no option option
Programmable 5-gas switching
no option yes
Temperature Capabilities
Degas Heating Mantles (2 stations) yes yes yes
Heating up to 400°C in steps of 1°C
Accuracy within 5°C of set point
Optional quartz mantles for higher temperatures
Optional programmable ramp/multi-step controllers
Analysis Heating Furnace (Autosorb -1-C) no no yes
Heating to 1,100°C with automatic calibration
Programmed ramp rates from 1 to 50°C/min.
Unlimited number of heating/cooling programs
Auto-Leveling Cooling Bath yes yes yes
Two liter standard (60 hours)
One liter, wide mouth (optional)
Cryostat no option option
More Autosorb-1 Series Specifications | Return to Autosorb-1 Series